BRICS AUTOMATIC AUTOCLAVING PROCESS

Category: Tags: , , , ,
Forms1

Description


Maintaining precise temperature control in the steam curing process for building materials is of utmost importance as it directly impacts various product characteristics, including curing time, hardness, and porosity. Thus, the selection of an automatic and intelligent autoclave steam curing system with flexible temperature control is crucial.

The autoclave pressure automatic control system is an integral component of this system, aimed at automating key aspects of the curing process. This includes the automation of autoclave door operations and the regulation of pressure and temperature inside the autoclave. This automation serves to enhance both the safety and the quality of the steam-cured products.

Automatic autoclaving systems have become the standard choice for newly established AAC (Autoclaved Aerated Concrete) factories. The design of our company’s automatic steaming system is based on pressure-time control. This design allows for the precise management of the autoclave curing process. Through a computer interface, operators can set various parameters for different stages of the autoclave curing process, including vacuuming, heating, maintaining a constant temperature, and pressure reduction.

The system then generates a pressure-time curve for each stage, which serves as a reference. What sets this system apart is its ability to automatically adjust the opening of valves based on the preset parameters and the main pressure within the autoclave. This level of automation ensures intelligent and precise control of the curing process, eliminating the need for constant manual intervention.

By maintaining uniform pressure changes at each stage and ensuring the stability of each autoclave curing cycle, this automated system significantly improves production efficiency. Moreover, it reduces the potential for human error and minimizes the impact of autoclave curing control on product quality, ultimately enhancing the product qualification rate.